OM5 Patch Cord,100 Gigabit Multimode Fiber Optic Jumper Cable
OM5 wideband multimode bend insensitive fiber optimized for multi-wavelengths transmission systems operating in the range of 850-950nm, enabling optimal support of emerging Shortwave Wavelength Division Multiplexing (SWDM) applications that reduce parallel fiber count by at least a factor of four to allow continued use of just two fibers (rather than eight) for transmitting 40 Gb/s and 100 Gb/s and reduced fiber counts for higher speeds.
OM5 meets TIA-492AAAE and draft IEC 60793-2-10 A1a.4 requirements while completely backward compatible with existing OM4 networks and applications. It meets RoHS compliant and the fiber patch cord is optically tested for insertion loss to ensure high quality.
Connector Type | LC/SC | Polish Type | UPC to UPC |
Fiber Mode | OM5 50/125μm | Wavelength | 850/1300nm |
40G Ethernet Distance | 440m at 850nm | 100G Ethernet Distance | 150m at 850nm |
Insertion Loss | ≤0.3dB | Return Loss | ≥20dB |
Fiber Grade | Bend Insensitive | Minimum Bend Radius | 7.5mm |
Attenuation at 850nm | 3.0 dB/km | Attenuation at 1300nm | 1.0 dB/km |
Effective Modal Bandwidth (at 850nm) | ≥4700 MHz·km | Effective Modal Bandwidth (at 953nm) | ≥2470 MHz·km |
Fiber Count | Duplex | Cable Diameter | 2.0mm |
Cable Jacket | PVC | Polarity | A(Tx) to B(Rx) |
Operating Temperature | -20~80°C | Storage Temperature | -40~80°C |
Quality Certification
Quality and standards are the foundation of FOCC. We are dedicated to providing customers with the outstanding, standards-compliant products and services.
FOCC has passed many quality system verifications, like ISO9001 and RoHS, established an internationally standardized quality assurance system and strictly implemented standardized management and control in the course of design, development, production, installation and service.
Quality Control System:
FOCC truly understands the value of performance to each fiber patch cables in whole line. Every cable FOCC provides must run through programming and an extensive series of platform diagnostic tests to prove its performance. In our test center, we care of every detail from staff to facilities—professionally trained staff and advanced test facilities, to ensure our customers to receive the cables with superior quality.
Professional Test Equipment-Our test program including: end-face inspection,3D interferometer test, single mode IL and RL testing, multimode IL and RL testing | ![]() |
![]() | Rigorous Test Process-Every cable will be cleaned to maintain end face free from contamination, avoiding affecting products' performance |
Smart & Reliable - Bendable Optical Fiber
The industry standard duplex fiber connector meets EIA/TIA 604-2 with ceramic ferrule for high speed cabling networks.Bend Insensitive Fiber Optic Cable Structure A unique refractive trench with low refractive index glass layer in BIF, which reduces in light dispersion upon twisting and bending, ensuring network transmission stably and fast.
OM5 Fiber Cable Structure
OM5 Multimode Fiber - Ready for Next-Generation Wideband Networks
As data rates increase in the data center, OM5 wideband multimode fiber (WBMMF) will allow use of Short Wavelength Division Multiplexing (SWDM) technology to transmit multiple signals (wavelengths) on one fiber, increasing the bandwidth of a single fiber by a factor of at least four.
Features
Zirconia Ceramic Ferrule Optimum IL and RL
Low insertion loss and high return loss, stable transmission
Max bending radius due to the excellent elasticity matallic tube
Strong tensile strength, prolong the service life
Application:
FTTH
LAN and Wan
CATV network,optical fiber data network
Active optical devices
Packing & Labeling
Eco-Friendly Packaging & Labeling
This easy to take and well-protected fiber optical cable package has been labeled and marked by FOCC as default. Customized label or package solution are available on request.